A9-30-10 220-230V 50Hz / 230-240V 60Hz Contactor

716.00800.00 (-11%)

In stock

SKU: IEC400553 Category:

A 9 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A… series 1-stack 3-pole contactors are of the block type design. – Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks – Control circuit: AC operated with laminated magnet circuit – Accessories: a wide range of accessories is available.

Technical Specification
MRP (Indian Rupees) Not for Retail Sale
Number of Main Contacts NO 3
Compatibility A Contactors
Max Mechanical Switching Frequency 3600 cycles per hour
Max Electrical Switching Frequency AC-1 600 cycles per hour, AC-2 / AC-4 300 cycles per hour, AC-3 1200 cycles per hour
Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-5-1, q = 40 °C 16 ampere, acc. to IEC 60947-4-1, Open Contactors q = 40 °C 26 ampere
Coil Consumption Average Holding Value 50 / 60 Hz 8 2 volt – ampere, Average Pull-in Value 50 Hz 74 volt – ampere, Average Pull-in Value 60 Hz 70 volt – ampere
Terminal Type Screw Terminals
Rated Operational Voltage Main Circuit 690 volt
Operate Time Between Coil De-energization and NO Contact Opening 4 … 11 millisecond, Between Coil Energization and NO Contact Closing 10 … 26 millisecond
Rated Control Circuit Voltage (Uc) 50 Hz 220-230V; 60 Hz 230-240V
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1 8 x Ie AC-3
Rated Operational Power AC-3 (Pe) (220 / 230 / 240 V) 2.2 KWT, (380 / 400 V) 4 KWT, (415 V) 4 KWT, (440 V) 4 KWT, (500 V) 5.5 KWT, (690 V) 5.5 KWT
Rated Operational Current DC-13 (Ie) (125 V) 1.1 / 138 ampere, (24 V) 6 / 144 ampere, (250 V) 0.55 / 138 ampere, (48 V) 2.8 / 134 ampere, (72 V) 2 / 144 ampere
Rated Operational Current AC-3 (Ie) (220 / 230 / 240 V) 55 °C 9 ampere, (380 / 400 V) 55 °C 9 ampere, (415 V) 55 °C 9 ampere, (440 V) 55 °C 9 ampere, (500 V) 55 °C 9 ampere, (690 V) 55 °C 7 ampere
Rated Operational Current AC-15 (Ie) (220 / 240 V) 4 ampere, (24 / 127 V) 6 ampere, (380 / 440 V) 3 ampere, (500 V) 2 ampere, (690 V) 2 ampere
Rated Operational Current AC-1 (Ie) (690 V) 40 °C 25 ampere, (690 V) 55 °C 22 ampere, (690 V) 70 °C 18 ampere
Rated Making Capacity AC-3 acc. to IEC 60947-4-1 10 x Ie AC-3
Rated Breaking Capacity acc. to IEC 60947-5-1 10 x Ie AC-15
Rated Frequency Limits 25 … 400 hertz
Rated Frequency (f) Supply Circuit 50 60 hertz
Number of Aux Contacts NO 1
Package Width 78 millimetre
Package Length 76 millimetre
Package Height 47 millimetre
Invoice Description A9-30-10 220-230V 50Hz / 230-240V 60Hz Contactor
Product Range A Contactors
Package Gross Weight 0.34 kilogram
Extended Product Type A9-30-10 220-230V 50Hz / 230-240V 60Hz
Ambient Air Temperature Close to Contactor for Storage -60 … +80 degree Celsius, Close to Contactor without Thermal O/L Relay (0.85 … 1.1 Uc) -40 … +55 degree Celsius, Close to Contactor Fitted with Thermal O/L Relay -25 … +55 degree Celsius, Close to Contactor without T
Rated Insulation Voltage (Ui) acc. to UL/CSA 600 volt, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 volt
Product Class Block Contactors
Total GST Percentage 18.00
HSN Number 85364900
Country of origin Bulgaria (BG) – Imported by ABB India Limited